390 WIN-PAK User Guide
The Output names displayed are those defaulted
by the system..
NOTE: If the point you need is not listed, make sure
the input, output point, or reader is active [the check
box is selected on its appropriate tab, within its board
configuration windows] and that no ADV exists for the
point or reader.
3 Strike Time is the amount of time the direct
point relay is pulsed/interlocked. The default for
this field is ten seconds, but can be set up to 60
seconds.
4 Control Mode is an auto-relock function. The
field defaults to "Strike off when door closed,"
but can be set to strike off when door opened.
Free Egress Input
Free Egress Input is used to indicate which input will
be used for the Free Egress device, and to configure
a door's free egress point. Free Egress Input can only
be linked to an input point.