9 If the check point is a reader rather than an input
point, you have the choice of using a valid card
read only, or allowing either valid or invalid cards
to activate a check point.
In this case an invalid card can activate a check
point without unlocking the door. In the Valid
Only column enter the type of card read re-
quired for the check point:
Y - for valid cards only
N - for any card (valid or invalid) will work
NOTE: Multiple Guard Tours can be run at the same
time. If you plan to run tours concurrently, do not use
the same unsequenced check points in both tours, as
doing so will make it difficult to tell which guard is
validating the point.
Use the Visible check box and Update button
on the Unsequenced Check Point window to
work with ADVs assigned to the check point
devices. Refer to the "Check Point Alarms"
section of this chapter for details.
On a specific tour, the checkpoints or readers
can not be shared on both the sequenced and
unsequenced tab. They may be defined multiple
times on one tour type but not both on the same
tour.
When you have finished adding all the
Unsequenced Check Points, click the Apply
button to save the information, and continue
working in the Guard Tour Record. Click OK to
save the information and exit the Guard Tour
Record.
Programming